1-24 series battery management system tester, high degree of automation, fast testing speed and high testing accuracy. With test function of overcharge protection, overcharge recovery, overdischarge protection, overdischarge recovery, overcurrent protection (overcharge current and overdischarge current), internal resistance, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection Time, balance current, balance voltage etc.

 

Product Advantages

 

1. Cycle: cycle times: 1 to 9999 times

2. Laboratory mode, can arbitrarily adjust the voltage value of a section

3 Can continuously provide charging and discharging current.

4. Using programming, the device carries out the number of cycles of each indicator of the protection board without interruption.

5. Log tracking, With log function, including the test of the entire process of operation records, abnormal records, can be used for the traceability of the test process.

6. Data processing, human-machine interface

7. Test data is saved in EXCEL file.

8. RS232 interface is used for the interface between the device and the host computer, which can ensure the stability and real-time data acquisition.

9. Accuracy calibration/software calibration

10. With sweeping code start function

11. MES system interface

12. Active equalization (can be customized)

13. Equalization current (customizable)

14. Communication protocol test (optional)

 

 

Test Functions

No.

Function

Range

Accuracy

unit

1

Self-consumption of single cell

0--500

±0.1

uA

2

Self-consumption

0--5000

±1

uA

3

Overcharge voltage

500--5000

±1

mV

4

Overcharge recovery voltage

500--5000

±1

mV

5

Overcharge voltage protection delay

0--10000

±1

mS

6

Overdischarge voltage

500--5000

±1

mV

7

Overdischarge recovery voltage

500--5000

±1

mV

8

Overdischarge voltage protection delay

0--10000

±1

mS

9

Overcharge protection current protection value

0.1--300

±0.01

A

10

Overcharge protection current protection delay

0--20000

±1

mS

11

Overdischarge protection current protection value

0.1--400

±0.01

A

12

Overdischarge protection current protection delay

0.1--20000

±1

mS

13

Equalization function

opening voltage

500--5000

±1

mV

14

Equalizing current

1--500

±1

mA

15

Charging current

0.1--300

±0.01

A

16

Discharging current

0.1--300

±0.01

A

17

Charging time

0--100

±1

S

18

Discharging time

0--100

±1

S

19

The difference of single cell self-consume

0-500

±0.1

uA

20

Resistance

0-999

±1

21

Short circuit protection time

0--5000

±1

uS

22

The charging voltage of single cell

500--5000

±1

mV

23

The discharging voltage of single cell

500--5000

±1

mV

24

Open circuit voltage

120000

±1

mV

25

Number of voltage analogs

24

0

PCS

 

Products Details

 

Hot Tags: 1-24 series 300a charge 400a discharge battery bms tester, China 1-24 series 300a charge 400a discharge battery bms tester manufacturers, suppliers, Lithium Ion Battery Pack Assembly Line, Laser Welding Machine, Bms Tester, 2 in 1 Insulation Paper Sticker and Sorting Machine, Batch and Date Coding Inkjet Printer, CNC Laser Welder