1-24S 50A120A BMS Testing Machine
video

1-24S 50A120A BMS Testing Machine

Brand: ACEY
Item No.:ACEY-BP24-50A120A
Compliance: CE Certified
Warranty: One Year warranty with lifetime support
Order(Moq): 1 set
Payment: T/T
Product Origin: China
Lead Time: 7 days
Send Inquiry
Product Introduction

Xiamen Acey New Energy Technology Co., Ltd. is a manufacturer and supplier of 1-24s 50a120a bms testing machine in China, offering factory-direct supply to customers worldwide. We also provide battery pack assembly equipment and turnkey production lines that comply with applicable CE requirements, along with OEM/ODM services and 24/7 after-sales support. Contact ACEY for product specifications, model selection advice, and a detailed quotation for 1-24s 50a120a bms testing machine.

 

1-24 Series Battery Management System Test Equipment

 

Products Description

 

1-24series battery management system tester, high degree of automation, fast testing speed and high testing accuracy. With test function of overcharge protection, overcharge recovery, overdischarge protection, overdischarge recovery, overcurrent protection (overcharge current and overdischarge current), internal resistance, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection Time, balance current, balance voltage etc.

 

It can test the BMS of MCN battery, LiFeO4 battery and cobalt acid battery.

 

This machine is required to be connected to a computer, the system generally requires an XP system, the interface of tester and computer is RS232.

 

Product Highlights

 

 

1. 1–24S BMS Testing: Supports battery management system testing for 1–24 series lithium-ion battery packs, including LiFePO4, NMC and lithium cobalt oxide batteries.

2. 50A Charging & 120A Discharging: Provides continuous charging and discharging current for evaluating BMS protection performance under different current conditions.

3. Microsecond-Level Short Circuit Protection Test: Supports short-circuit protection response testing with microsecond-level measurement, with a specified test range of 0–5000 μs.

4. Individual Cell Self-Consumption Measurement: Measures self-consumption current of individual cells and the overall BMS, with a single-cell measurement accuracy of ±0.1 μA.

5. Comprehensive Protection Testing: Tests overcharge, overdischarge, overcurrent, voltage recovery, protection delays and internal resistance to evaluate BMS protection functions.

6. Cell Disconnection Detection: Identifies disconnected cell voltage sampling signals, helping verify the BMS response to abnormal wiring conditions.

7. Cell Balancing Performance Test: Measures balancing opening voltage and balancing current to evaluate battery pack balancing performance.

8. Programmable Cycle Testing: Supports 1–9999 test cycles with programmable test sequences for continuous and repeatable BMS performance evaluation.

9. Test Data Recording & MES Integration: Supports barcode scanning, operation log tracking, Excel data export and MES connectivity for test data management and traceability.

 

 

Test Functions

 

No.

Function

Range

Accuracy

unit

1

Self-consumption of single cell

0--500

±0.1

uA

2

Self-consumption

0--5000

±1

uA

3

Overcharge voltage

500--5000

±1

mV

4

Overcharge recovery voltage

500--5000

±1

mV

5

Overcharge voltage protection delay

0--10000

±1

mS

6

Overdischarge voltage

500--5000

±1

mV

7

Overdischarge recovery voltage

500--5000

±1

mV

8

Overdischarge voltage protection delay

0--10000

±1

mS

9

Overcharge protection current protection value

0.1--50

±0.01

A

10

Overcharge protection current protection delay

0--20000

±1

mS

11

Overdischarge protection current protection value

0.1--120

±0.01

A

12

Overdischarge protection current protection delay

0.1--20000

±1

mS

13

Equalization function

opening voltage

500--5000

±1

mV

14

Equalizing current

1--500

±1

mA

15

Charging current

0.1--30

±0.01

A

16

Discharging current

0.1--120

±0.01

A

17

Charging time

0--30

±1

S

18

Discharging time

0--60

±1

S

19

The difference of single cell self-consume

0-500

±0.1

uA

20

Resistance

0-999

±1

mΏ

21

Short circuit protection time

0--5000

±1

uS

22

The charging voltage of single cell

500--5000

±1

mV

23

The discharging voltage of single cell

500--5000

±1

mV

24

Open circuit voltage

102000

±1

mV

25

Number of voltage analogs

24

0

PCS

 

Parameter of the main loop test:

Project

Parameter

Voltage

102000mV

Voltage resolution

1mV

Voltage accuracy

±0.1%

Discharging current

0.1A ~120A

Current resolution

1mA

Current accuracy

±(0.1%)

Other

The charging and discharging circuits are completely separated

 

Parameter of every series cell:

Project

Parameter

Output voltage of every cell

500mV ~ 5000mV

Input voltage of every cell

500mV ~ 5000mV

Voltage resolution

1mV

Voltage accuracy

±0.05%

Equalization current

500mA

 

Products Details


1-24 BMS tester BMS Tester BMS TestingMachine

 

FAQ

 

Q: What types of battery packs can this BMS Tester test?

A: ACEY-BP24-50A120A supports BMS testing for lithium-ion, LiFePO4, and lithium cobalt oxide battery packs with 1–24 series configurations.

Q: Can this BMS Tester detect microsecond-level short-circuit protection and disconnected cell signals?

A: ACEY-BP24-50A120A supports microsecond-level short-circuit protection testing and disconnect detection to identify missing or disconnected cell voltage sampling signals. It also measures individual cell self-consumption current.

Q: Does the BMS Tester support automated testing and test data recording?

A: ACEY-BP24-50A120A supports programmable test sequences with 1–9999 cycles, automatic test execution, and operation log tracking. Test results can be exported to Excel, with RS232 communication and an optional MES interface for data management.

 

 

 

Hot Tags: 1-24s 50a120a bms testing machine, China 1-24s 50a120a bms testing machine manufacturers, suppliers