Optional 1-32Series 500A Charge 800A Discharge Battery Management System Test Equipment
Item No.: ACEY-BP32-500A800A
Order(Moq): 1 set
Compliance: CE Certified
Package: Plywood Case
Product Origin: China
Warranty: One-year warranty with lifetime support
Payment: T/T, Western Union, PayPal, Ali Trade Assurance
Optional 1-32Series 500A Charge 800A Discharge Battery Management System Test Equipment
Products Description
ACEY-BP32-500A800A bms tester can detect the function of the lithium battery protection board and various performance indicators. It is especially suitable for factory inspections for mass production. It is developed using the principle of capacitor simulation battery charging and discharging, and has multiple functions: Simple operation, fast detection speed, etc.
Product Advantages
(1)Input power supply: 180~240V 50/60HZ,Power: 5000W
(2)Power standard supply: AC 220V/50HZ,Range:±10%
(3)The voltage of chare and discharge:5000mV ~160000mV
(4)It can test and set the voltage range when this machine is charging and dischagring..
(5)Current accuracy::±(0.1%FS+0.1%RD)
(6)Voltage accuracy±(0.1%FS+0.1%RD)
(7)Current resolution:1mA (smallest unit)
(8)Voltage resolution:1mV (smallest unit)
(9)Cycles:1~9999
(10)With log function, including operation records and exception records during the whole process of testing, which can be used for traceability of the testing process.
(11)Data processing, human-machine interface
(12)Export data formation:Excel
(13)Interface:RS232
(14)Accuracy calibration/software calibration
(15)With scan code start function
(16)MES system connection
Test Functions
No. |
Function |
Range |
Accuracy |
unit |
1 |
Self-consumption of single cell |
0--500 |
±0.1 |
uA |
2 |
Self-consumption |
0--5000 |
±1 |
uA |
3 |
Overcharge voltage |
500--5000 |
±1 |
mV |
4 |
Overcharge recovery voltage |
500--5000 |
±1 |
mV |
5 |
Overcharge voltage protection delay |
0--10000 |
±1 |
mS |
6 |
Overdischarge voltage |
500--5000 |
±1 |
mV |
7 |
Overdischarge recovery voltage |
500--5000 |
±1 |
mV |
8 |
Overdischarge voltage protection delay |
0--10000 |
±1 |
mS |
9 |
Overcharge protection current protection value |
0.1--500 |
±0.01 |
A |
10 |
Overcharge protection current protection delay |
0--20000 |
±1 |
mS |
11 |
Overdischarge protection current protection value |
0.1--800 |
±0.01 |
A |
12 |
Overdischarge protection current protection delay |
0.1--20000 |
±1 |
mS |
13 |
Equalization function opening voltage |
500--5000 |
±1 |
mV |
14 |
Equalizing current |
1--500 |
±1 |
mA |
15 |
Charging current |
0.1--200 |
±0.01 |
A |
16 |
Discharging current |
0.1--200 |
±0.01 |
A |
17 |
Charging time |
0--30 |
±1 |
S |
18 |
Discharging time |
0--60 |
±1 |
S |
19 |
The difference of single cell self-consume |
0-500 |
±0.1 |
uA |
20 |
Resistance |
0-999 |
±1 |
mΏ |
21 |
Short circuit protection time |
0--5000 |
±1 |
uS |
22 |
The charging voltage of single cell |
500--5000 |
±1 |
mV |
23 |
The discharging voltage of single cell |
500--5000 |
±1 |
mV |
24 |
Open circuit voltage |
102000 |
±1 |
mV |
25 |
Number of voltage analogs |
32 |
0 |
PCS |
Other parameter
Project |
Parameter |
Consumption current measuring range |
1 ~ 5000uA |
Consumption current measuring resolution |
0.1uA |
Resistance |
ACIR:0-999mr |
Protection time |
Overcurrent protection time:0-999ms; Short circuit protection time:0-999us |
1 channel signal voltage output: |
500~5000mV |
AD/DA |
AD:16bit DA:16bit |
Discharging model |
CC |
24 analog cells |
Input/output:500~5000mV, voltage accuarcy:±0.1% |
Communication rate |
2channels SBS communication rate:10~100Kbps |
Others |
Voltage sample:0~5000mV accuarcy:±0.1% |
Protect function |
Overall protection (including reverse connection protection, voltage lower protection, voltage upper protection, and current upper protection), CC charging protection (abnormal voltage trend protection, abnormal charging current fluctuation protection, abnormal voltage fluctuation protection), CC discharge protection (including Voltage trend abnormal protection, discharge current fluctuation abnormal protection, voltage fluctuation abnormal protection) |
Communication |
Interface RS232/DB9 Communication rate interface:38400 All communication ports of the equipment are isolated, with lightning protection design |
circuit structure |
Modular structure, can be replaced and repaired in time with spare parts and spare parts. |
Machine architecture |
Split cabinet |
Safety level |
EN60950,GB4943 |
noise |
As per IEC62040-3, ≤70dBA |
IP Level |
IP20 |
Color |
Subject to actual conditions |
lightning protection |
GB17626 level:II |
Cooling |
Forced air cooling, at least 20cm space between exit and entry |
Start pulse voltage |
Equipment testing, the maximum allowable pulse voltage at the time of starting the execution process ≤ (set the number of test strings * set the single voltage)*110%, T≤500uS; |
Start pulse current |
For equipment testing, the maximum allowable pulse current at the time of starting the overcurrent test process is less than or equal to the upper limit of the set overcurrent protection value*110%, T≤1mS |
Wiring method |
Spring crimping |
Cabinet size |
799(L)*1100(W)*960mm(L) |
Products Details
Hot Tags: Optional 1-32Series 500A Charge 800A Discharge Battery Management System Test Equipment, China Optional 1-32Series 500A Charge 800A Discharge Battery Management System Test Equipment manufacturers, suppliers, Heat Shrinking Machine, Portable Fiber Laser Welding Machine 500w, Lithium Spot Welding Machine, Battery Paper Pasting Machine, Battery Integrated Tester, Lithium Ion Battery Manufacturing Machines
You Might Also Like