Battery Formation And Grading System
Model No.: ACEY-BCT510-256R
Battery Types:Cylinder Battery 32140/33140/34189(Customized)/Etc
Warranty:1 year
MOQ:1 set
Package:Plywood Case
Xiamen Acey New Energy Technology Co.,Ltd is one of the most reliable manufacturers and suppliers of battery formation and grading system in China. Please rest assured to buy high quality products made in China here from our factory. Contact us for customized service.
256 Channels 5V 10A Energy Saving Feedback Battery Formation and Grading System For BAK GOTION EVE CATL Cylinder Cell
Equipment Features and Appearance Structure
System Features:
●Single point independent, independent constant current and constant voltage source, stable without impact. Functions such as start, stop, pause, resume and protection can be realized.
●The equipment accuracy is 0.05%, the data recording time is 1 second/time, and the stability is high.
●The software has powerful functions and friendly man-machine interface.
●Four-wire test interface to ensure high measurement accuracy. Modular design concept, easy to maintain.
The structure of this equipment is mainly composed of the following parts:
1.Independent CPU board, double keyboard board, unified sending control of the whole cabinet;
2.8-channel constant current and constant voltage control module;
3.Bidirectional AC/DC inverter module;
4.Tray-type automatic clamping and clamping (cylinder) mode.
System Structure and Working Principle
System Composition
1.Lithium battery is converted into capacity equipment.
2.Computer with USB interface (bring your own).
3.USB to 485 interface converter or five types of communication lines and crystal heads.
4.Battery scanning system.
5.ACEY product software.
System Principle
Lithium battery formation and grading system is connected and controlled by a computer to send commands and collect data; the keyboard can manually operate the equipment to display parameters and status; the constant current board is commanded by the CPU and has constant current and constant voltage functions; when the battery is charged, the two-way power supply converts alternating current to 14V Direct current, through the constant current board to realize the charging control and detection of the battery; when the battery is discharged, the process is opposite to the charging process. First, the battery voltage is raised to 15V through the constant current board, and then the two-way power supply converts the direct current into alternating current and feeds it directly. into the AC power distribution network of the factory, thus realizing the energy feedback of battery discharge electric energy.
Significant power saving effect: According to actual measurement, the power consumption of the device during charging is more than 40% lower than that of traditional devices, the comprehensive power saving rate is more than 60%, and the power consumption is more than 60%, saving a lot of costs for battery manufacturers.
Specification
|
Structure of equipment |
|
|
Number Of Device Channels |
The whole machine has a total of 256 channels |
|
Dimensions |
L1684*W1091*H1640 |
|
Chassis Color |
Standard gray black (can be customized) |
|
Fixture Form |
Customized fixture, using pallet structure, cylinder open clamp. |
|
Fixture Spacing |
37mm |
|
Support Battery Specifications |
Length: 120-185mm; Diameter: 34/35mm |
|
Channel Control Mode |
Each battery has an independent constant current and constant voltage source, which is stable and without impact. can be realized |
|
start, stop, pause, resume and protect |
|
|
Each channel has independent constant voltage and constant current hardware control circuit |
|
|
Working Power |
The charging current and discharging current accuracy of each channel can be automatically calibrated by software |
|
Power Factor |
Three-phase five-wire system AC380V±10%, 50HZ |
|
Ac Current Distortion Rate |
≥0.99 |
|
Power Department Efficiency Index |
≤2% |
|
Working Power Consumption |
Charge ≥80%, discharge ≥70% |
|
Equipment Failure Rate |
<1% |
|
Working Environment |
Temperature -10~40, relative humidity 80% |
|
Cooling Method |
TNatural air intake, upward exhaust |
|
Power Section Protection Function |
Grid voltage over-limit protection Power grid frequency over-limit protection |
|
Channel parameters |
|
|
Voltage measurement range |
DC 0~5V |
|
battery voltage range |
Charging DC 0~4.5V; Discharging DC 4.5~2V |
|
Constant voltage range |
DC 2~4.5V |
|
Voltage accuracy |
±(0.5‰ reading+0.5‰ full scale), |
|
Voltage control resolution |
0.1mV |
|
Voltage sampling resolution |
0.1mV |
|
Voltage stability |
≤(±1mV) |
|
Current range |
Charging DC 50mA~20A; Discharging DC 50mA~20A |
|
Current accuracy |
±(0.5‰reading+0.5‰full scale) |
|
Current control resolution |
1mA |
|
Current sampling resolution |
0.1mA |
|
Current stability |
≤(±1mA) |
|
Current Rise Time (90% Load) |
≤50MS |
|
Channel startup time (90% load) |
≤50MS |
|
Software function |
|
|
way to control |
Computer control equipment work, whole cabinet control, with scanning system |
|
communication method |
485 serial communication (baud rate 57600) / TCP communication |
|
Process settings |
Up to 32 steps and 256 cycles can be set |
|
charging mode |
Constant current, constant voltage |
|
Charging cut-off condition |
Voltage, current, time, capacity |
|
discharge mode |
Constant current, constant power, constant resistance |
|
Discharge cut-off condition |
voltage, time, capacity |
|
Protective function |
Charging overvoltage protection, charging undervoltage protection Discharge overvoltage protection, discharge undervoltage protection Charge and discharge voltage trend protection Voltage fluctuation protection Current fluctuation protection Battery reverse connection protection, hardware protection method Power tube short circuit protection Channel capacity alarm protection (timeout protection) Voltage sampling drop protection Voltage outlier protection Capacity outlier protection Open the voltage detection before the process starts, and stop the channel whose open voltage exceeds the limit Power-off protection, data breakpoint recovery |
|
Time Range Time Precision |
0 to 3000 minutes/step, time unit: min ≤±1‰ |
|
Sampling And Inspection Cycle Battery Sorting |
1S-60S |
Products Details



Hot Tags: battery formation and grading system, China battery formation and grading system manufacturers, suppliers, Battery Cell Formation Equipment, Battery Formation And Grading System, Thermostatic Prismatic Battery Charge Discharge Tester, 5V 6A Battery Charge Discharge Test Equipment, Prismatic Battery Capacity Tester, Battery Testing System
You Might Also Like