Lithium Battery Cycle Charge Discharge System
Model No.: ACEY-HRCDS-5V60A-80CH
Battery Type: Li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on
Order(Moq): 1 set
Package: Plywood Case
Product Origin: China
Warranty: One-year warranty with lifetime support
Payment: T/T, Western Union, PayPal, Ali Trade Assurance
Xiamen Acey New Energy Technology Co.,Ltd is one of the most reliable manufacturers and suppliers of lithium battery cycle charge discharge system in China. Please rest assured to buy high quality products made in China here from our factory. Contact us for customized service.
5V 60A 80 Channel Lithium Battery Cycle Charge Discharge System
Product Description
ACEY-HRCDS-5V60A-80CH lithium battery charge discharge machine is widely used in the development, production, and quality control of various types of batteries to test battery cycle life, capacity and performance, etc.
Working environment and technical parameter
- Stand alone power supply: AC 220V±10%, frequency: 50HZ±5%.
- Power supply of the whole cabinet: AC 380V±10%, frequency: 50HZ±5%.
- Maximum input power of the whole cabinet: 34.3 kW (80CH)
- Working temperature: 0℃ - 45℃.
- Humidity: less than ≤ 85%R.H (non-condensing).
- No severe shake, no corrosive gases, no flammable or explosive gases around.
- Resolution: AD 16 bit.
|
No. |
Item |
ACEY-HRCDS-5V60A |
||
|
1 |
Main channels |
8CH/module |
||
|
2 |
Channel working mode |
Completely independent |
||
|
3 |
Main channel working mode |
Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV. Discharge: CD, CP, CR, DCCV Still |
||
|
Main channel test cutoff condition |
Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. |
|||
|
4 |
Main channel Voltage |
Single channel test range |
0V-5V |
|
|
Min. discharge voltage |
1V |
|||
|
Accuracy |
±0.05%FS |
|||
|
Resolution |
0.1mV |
|||
|
Main channel Current |
Single channel test range |
±60A |
||
|
Min. output current |
60mA |
|||
|
Accuracy |
±0.05%FS |
|||
|
Resolution |
1mA |
|||
|
Current start response time |
<10ms(10%FS~90%FS) |
|||
|
Time |
Resolution |
10mS |
||
|
Auxiliary temperature (Optional) |
Range |
﹣20℃~100℃ |
||
|
Accuracy |
±1℃(0℃~70℃) |
|||
|
Resolution |
0.1℃ |
|||
|
Power |
Output power |
Single channel continuous working power300W |
||
|
Stability |
±0.1%FS |
|||
|
5 |
Communication |
LAN |
||
|
6 |
Control program |
Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. |
||
|
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. |
||||
|
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. |
||||
|
Cycle time |
Max. 9999 |
|||
|
Programmable step |
Max. 9999 |
|||
|
Nested loop |
Max. 10 layers |
|||
|
Step time range |
Support h, min, s |
|||
|
Data record |
Time≥20ms,Voltage≥0.05%FS,Current ≥0.05%FS |
|||
|
Program feature |
Each step has one or multiple exit |
|||
|
7 |
Data display |
Cycle list |
Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. |
|
|
Process list |
Process number, working mode, process time, capacity, power, medium voltage, cut-off voltage, cut-off current, etc. |
|||
|
Detail list |
Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. |
|||
|
8 |
Data export |
Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. |
||
|
9 |
Data saving |
Save as files |
||
|
10 |
Curves type |
X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity |
||
|
Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc |
||||
|
11 |
Software protection |
Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection |
||
|
Hardware protection |
Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection. |
|||
|
Warning function |
Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. |
|||
|
12 |
Barcode scan |
Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system. |
||
|
13 |
Sampling terminals |
Four-polar sampling. Copper nose or other fixture. |
||
|
14 |
Energy consumption |
Discharge power feedback to grid |
||
|
15 |
Cooling method |
Forced Fan-cooled |
||
|
Noise |
Less than 70dB |
|||
|
IP grade |
IP20 |
|||
|
16 |
Repair |
Modularized structure. Can be replaced or repair with spare parts. |
||
Product advantages
- High reliability, low noise, and high energy density with flexible lab use (220V single module).
- Grid feedback (≥70% efficiency) saves power and cooling costs.
- Contact impedance monitoring prevents safety risks from poor connections.
- Smooth CCCV charging avoids micro-shorts, overheating, or protection triggers.
- High-accuracy sampling (16-bit ADC/DAC) for stable voltage/current data.
- Dynamic load protection prevents sparks, current shocks, and component damage.
- Voltage clamp function protects batteries/PCBs during protection triggers.
- ECD/EVD protection filters out batteries that fail prematurely.
- 3rd-party device control (e.g., temperature chambers) with synchronized data logging.
- Capacity calibration sets discharge capacity as a cycle test benchmark.
- Data statistics for real-time and historical analysis.
Equipment Parameter
|
Cabinet size |
600*800*1980mm |
|
Weight |
≤300KG |
|
Channels number |
80CH |
|
Remarks :The above picture is for reference only, subject to the kind! |
|
Products Display


Hot Tags: lithium battery cycle charge discharge system, China lithium battery cycle charge discharge system manufacturers, suppliers, Battery Pack Production Line, Battery Pack Fabrication Line, Lithium Ion Battery Manufacturing Machines, Lithium Ion Battery Pack Assembly Line, Battery Pack Assembly Line, Battery Pack Assembly Equipment
You Might Also Like