20V 5A Ni-MH HEV Hybrid Car Battery Reconditioning Machine Repair Equipment
video

20V 5A Ni-MH HEV Hybrid Car Battery Reconditioning Machine Repair Equipment

Item Name: Battery Repair Machine
Item No.: ACEY-ACTS-20V5A-GGS
Order(Moq): 1 set
Compliance: CE Certified
Package: Plywood Case
Product Origin: China
Warranty: One-year warranty with lifetime support
Payment: T/T, Western Union, PayPal, Ali Trade Assurance
Send Inquiry
Product Introduction

 

20V 5A Nicad Ni-MH Hybrid Car Battery Reconditioning Machine Battery Repair Maintenance Equipment

 

 

Product Description

 

Application:This equipment is primarily designed for cycle life testing and quality evaluation of various battery types-including lithium-ion, lead-acid, nickel-cadmium, and nickel-metal hydride batteries-in both production line and laboratory environments.

 

Testing Capabilities:The system delivers comprehensive testing capabilities including cycle life evaluation, capacity measurement, charge-discharge characterization, charge retention analysis, efficiency assessment, and overcharge/overdischarge tolerance testing.

 

 

Working Environment and Technical Parameters

 

1. Power supply: AC220V ±10%, 50Hz ±5%
2. Operating temperature: 25℃ ±3℃
3. Relative humidity: ≤85% (non-condensing)
4. Environment must be free from strong vibration
5. No corrosive, flammable or explosive gases permitted in the surrounding atmosphere

 

product parameter

 

No. Item ACEY-ACTS-20V5A-GGS
1 Main channels 8CH/module
2 Channels working mode Independently
3 Main channel working mode Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV
Discharge: CD, CP, CR
Still
Ending condition of main channel Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, Temperature (NTC detection temperature and GGS temperature), etc.
4 Main channel Voltage Test range of voltage 0V-20V
Min. discharge voltage 1.5V
Accuracy ±0.02%FS+0.02%RD(@25±3℃)
Resolution 0.1mV
Main channel Current Test range of current ±5A
Min. output current 20mA
Accuracy ±0.02%FS+0.02%RD(@25±3℃)
Resolution 1mA
Current start response time <10ms
Time Resolution 10ms
Power Output power Single channel continuous working power 100W
Stability ±0.05%FS+0.05%RD
Auxiliary channel parameter cutoff function Main channel step can be set to stop or jump when auxiliary channel signal reach to a certain condition.
5 ACTS Communication LAN
6 GGS Communication (Optional) SMBUS, I2C, HDQ
Support reading 100kHz and 400kHz communication frequency battery information (software can be set and switched)
Support single channel independent operation of different data communication protocols. (If GGS communication and INA231 communication are selected)
Support multi-channel simultaneous sampling, and the data recording interval of the same channel is ≥ 1s (The same table as the charge and discharge data)
7 Control program Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online.
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc.
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature.
Cycle time Max. 9,999
Programmable step Max. 9,999
Nested loop Max. 10 layers
Step time range No limit, support h, min, s
Data record Maximum recording time:10ms, voltage≤0.02%FS, current ≤0.02%FS
Program feature Each step has one or multiple exit
Barcode scan Support
8 Data display Cycle list Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc.
Process list Process number, working mode, process time, capacity, power, medium voltage, cut-off voltage, cut-off current, etc.
Detail list Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc.
9 Data export Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc.
10 Data saving Save as files
11 Curves type X-coordinate: total time, charge discharge capacity, cycle time
Y-coordinate: total voltage, current, capacity, power, cell temperature
12 Software protection Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection
Hardware protection Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP.
Warning function Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically.
13 Sampling terminals Four-polar sampling. Crocodile clip or other clips.
14 Energy consumption Heat dissipation
15 Cooling method Forced Fan-cooled
16 Voice Less than 70dB(Single set)
IP grade IP20
17 Repair Modularized structure. Can be replaced or repair with spare parts.

 

Equipment Parameters

Cabinet size 920*722*1805mm
Weight ≤300KG
Channel number 8/40/80CHS
Remarks :The above picture is for reference only, subject to the kind!

 

Products Details

 

Hybrid Battery Reconditioning Equipment

battery reconditioning machine

battery repair machine

 

battery maintenance machine

 

Hot Tags: 20v 5a ni-mh hev hybrid car battery reconditioning machine repair equipment, China 20v 5a ni-mh hev hybrid car battery reconditioning machine repair equipment manufacturers, suppliers, 200V 300A Regenerative Battery Pack Testing Machine, 30V 20A Battery Pack Charge Discharge Test Equipment, 500V 500A Battery Charge Discharge Test Equipment, 60V 30A Regenerative Battery Pack Test System, Battery Pack Test System, Battery Pack Testing Machine

Send Inquiry

whatsapp

Phone

E-mail

Inquiry